VMware 2V0-13.25 Actual Exam Questions
100 Questions & Answers
Continue with free 2V0-13.25 practice questions and answers covering VMware Cloud Foundation security, automation, storage and availability. Review questions 6β10 and check your understanding. Select Reveal Solution after choosing your answer.
As part of the VMware Cloud Foundation (VCF) logical design, the architect documented the following requirement:
The solution must include high security hardening levels to meet military compliance standards.
Which two physical design decisions will meet this security requirement in the workload domain? (Choose two.)
Reveal Solution
Using an internal military Root CA and internal NTP sources supports the required hardened environment.
An architect is designing a new VMware Cloud Foundation (VCF) solution. The customer has multiple independent business units, some with their own Active Directory (AD) instances, and each needs a dedicated development environment.
The customer wants to use VCF Automation so employees can provision and manage their own resources within governance boundaries.
Which two design decisions should the architect include for VCF Automation? (Choose two.)
Reveal Solution
Separate tenants provide isolation for each business unit, while dedicated AD instances support the existing authentication structure.
An architect is designing a VCF-based private cloud with these requirements:
β’ Co-locate application workloads with VCF management components in the same vSphere cluster.
β’ Shared storage must be current during a single-site outage.
β’ Two sites, no more than 10 miles apart, are connected with high-speed networking.
β’ Protect against an outage of a single availability zone.
Which two storage technologies could meet the stated requirements? (Choose two.)
Reveal Solution
VMFS on FC and vSAN can support the stated stretched-site availability design.
As part of the VCF logical design, an architect determined that a VCF Private Cloud will contain multiple VCF instances within a single VCF Fleet.
The architect documented the following requirements when using VCF Operations:
β’ Monitoring downtime must be minimized.
β’ Alerting downtime must be minimized.
Which design decision supports these requirements?
Reveal Solution
A High Availability configuration with remote Collector nodes maintains monitoring and alerting if one node fails.
As part of the initial design workshop, one customer stakeholder states:
All Virtual Machines must be encrypted.
How would the architect classify this statement?
Reveal Solution
It defines a mandatory condition that the solution must meet, so it is a requirement.
Get all 100 questions and answers in the Premium PDF.